최신 CATE 000-109 무료샘플문제:
1. An administrator adds a new virtual target device to a vhost adapter that already had target devices on it. The client LPAR does not detect the new disk and the following error has been logged in the errlog:
What is the most likely cause for this situation?
A) The queue_depth parameter of the new drive is larger than those of the other drives provided by the host adapter
B) The intr_lsi of the host adapter is set higher than that needed by the new drive
C) The intr_priority of the host adapter is set lower than that needed by the new drive.
D) The max_transfer parameter of the new drive is smaller than the rate already reported by the host adapter
2. A customer wants to compare a number of models within the POWER7 family to determine which is the best fit for their requirements. What centralized source would allow them to compare availability of Capacity on Demand and supported Hot-plug functions?
A) POWER Reference Guide
B) Techline POWER7 compendium
C) POWER7 Press kit
D) Facts and Features Report
3. A secondary site is being deployed for application availability and site failover. Servers of identical model and type have been ordered and delivered to the new location.
Additional PowerVM activation keys were obtained for the original location to allow more than 32000 WWNs and enable Active Memory Sharing (AMS).
How can the duplicate systems be updated to enable these additional features?
A) Contact IBM Support to generate the one-time password required to administer the PowerVM activation keys.
B) The activation keys must be exported using the PowerVM option within the Capacity On Demand (CoD) panel on the HMC.
C) Create a system plan of the existing configuration and deploy this to the duplicate configuration.
D) Activation keys are generated for a specific system and must be generated for each new server in the failover site.
4. An administrator plans to implement Active Memory Expansion on several LPARs on a Power 770 system. Which tool should be used to determine the recommended LPAR settings for Active Memory Expansion?
A) amestat
B) amemon
C) amelpar
D) amepat
5. An administrator wants to add vSCSI adapters to a new client using the existing mapping schema. The slots will be 40/41 on the VIO Server. Given the current properties of the VIO server, what must be done to accomplish this?
A) Change the Maximum virtual adapters to 50 in the VIOS partition profile.
Create the vSCSI adapters on slots 40/41 in the VIOS partition profile and map them to the
new client.
Shutdown and reactivate the VIOS.
B) Use DLPAR to increase the Maximum virtual adapters to 50.
Use DLPAR to create the vSCSI adapters on slots 40/41 and map them as "Any client
partition can connect".
C) Change the Maximum virtual adapters to 50 in the VIOS partition profile.
Create the vSCSI adapters on slots 40/41 in the VIOS partition profile and map them as
"Any client partition can connect".
Reboot the VIOS.
D) Use DLPAR to increase the Maximum virtual adapters to 50.
Use DLPAR to create the vSCSI adapters on slots 40/41 and map them to the new client.
질문과 대답:
질문 # 1 정답: D | 질문 # 2 정답: D | 질문 # 3 정답: D | 질문 # 4 정답: D | 질문 # 5 정답: A |